{"product_id":"general-electric-indoor-current-instrument-transformer-jct-0c-600v-750x123624","title":"GENERAL ELECTRIC Vernova Current Instrument Transformer JCT-0C 600V 750X123624","description":"\u003ch1 style=\"text-align: center;\"\u003eGENERAL ELECTRIC\u003c\/h1\u003e\n\u003ch2 style=\"text-align: center;\"\u003eVernova Current Instrument Transformer JCT-0C\u003c\/h2\u003e\n\u003ch3\u003eCondition: New\u003c\/h3\u003e\n\u003ch3\u003eSize: 10kV - 0.6kV \/ 50 - 60 Hz \/ Ratio 400:5 AMPS\u003c\/h3\u003e\n\u003ch3\u003eMPN\/Model: 750X123624\u003c\/h3\u003e\n\u003cp\u003eDescription: \u003c\/p\u003e\n\u003cul data-processed=\"true\" class=\"U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003e\u003cb data-processed=\"true\" class=\"Yjhzub\"\u003eType:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCurrent Transformer (CT).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003e\u003cb data-processed=\"true\" class=\"Yjhzub\"\u003eLocation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eIndoor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBQ\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003e\u003cb data-processed=\"true\" class=\"Yjhzub\"\u003eRatio:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e400:5 A. This means that when 400 amps of current flow through the primary winding, 5 amps are induced in the secondary winding.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBg\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003e\u003cb data-processed=\"true\" class=\"Yjhzub\"\u003ePhase:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSingle-phase.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBw\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003e\u003cb data-processed=\"true\" class=\"Yjhzub\"\u003eBasic Impulse Level (BIL):\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e10 kV. This is the maximum transient overvoltage the transformer can withstand.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQCA\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003e\u003cb data-processed=\"true\" class=\"Yjhzub\"\u003eFrequency:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e50\/60 Hz.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQCQ\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003e\u003cb data-processed=\"true\" class=\"Yjhzub\"\u003eMetering Class:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.3 B0.2. This specifies the transformer's accuracy for metering purposes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQCg\"\u003e\n\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003e\u003cb data-processed=\"true\" class=\"Yjhzub\"\u003eRating Factor:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2.0. This indicates the allowable continuous current as a multiple of the rated current without exceeding the specified temperature rise.\u003c\/span\u003e\u003cspan data-processed=\"true\" class=\"\"\u003e\u003cspan data-processed=\"true\" data-animation-atomic=\"\" class=\"vKEkVd\"\u003e \u003cbutton data-processed=\"true\" data-ved=\"2ahUKEwj4vvvdneCPAxWGJkQIHSK9KisQye0OegQIAxAL\" class=\"rBl3me\" aria-label=\"View related links\" data-icl-uuid=\"20cee600-3900-4e25-a6e1-fc6cc45116e0\" data-amic=\"true\" tabindex=\"0\"\u003e\u003cspan data-processed=\"true\" class=\"wiMplc ofC0Ud\"\u003e\u003csvg viewbox=\"0 0 24 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" height=\"12px\" width=\"12px\" fill=\"currentColor\"\u003e\u003cpath d=\"M3.9 12c0-1.71 1.39-3.1 3.1-3.1h4V7H7c-2.76 0-5 2.24-5 5s2.24 5 5 5h4v-1.9H7c-1.71 0-3.1-1.39-3.1-3.1zM8 13h8v-2H8v2zm9-6h-4v1.9h4c1.71 0 3.1 1.39 3.1 3.1s-1.39 3.1-3.1 3.1h-4V17h4c2.76 0 5-2.24 5-5s-2.24-5-5-5z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv data-processed=\"true\" role=\"heading\" aria-level=\"3\" class=\"otQkpb\"\u003eFunctional use\u003c\/div\u003e\n\u003cdiv data-processed=\"true\" data-hveid=\"CAUQAA\" class=\"Y3BBE\"\u003eInstrument transformers are high-accuracy electrical devices used to:\u003c\/div\u003e\n\u003cul data-processed=\"true\" class=\"U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAYQAA\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003eSafely isolate metering and control circuits from high-voltage or high-current power circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAYQAQ\"\u003e\u003cspan data-processed=\"true\" class=\"T286Pc\"\u003eStep down a large primary current to a small, measurable secondary current for monitoring and protection devices\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GENERAL ELECTRIC","offers":[{"title":"Default Title","offer_id":48736678904045,"sku":"CWY515","price":196.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0602\/6461\/2077\/files\/F834E533-F55E-48DD-8371-8DD36AAE5664.jpg?v=1758129732","url":"https:\/\/paywut.com\/en-ie\/products\/general-electric-indoor-current-instrument-transformer-jct-0c-600v-750x123624","provider":"PayWut","version":"1.0","type":"link"}