{"product_id":"toshiba-carrier-t-shaped-heat-recovery-branching-joint-kit-rbm-bt14ful","title":"TOSHIBA CARRIER T-shaped Heat Recovery Branching Joint Kit RBM-BT14FUL","description":"\u003ch1 style=\"text-align: center;\"\u003eTOSHIBA CARRIER\u003c\/h1\u003e\n\u003ch2 style=\"text-align: center;\"\u003eT-shaped Heat Recovery Branching Joint Kit\u003c\/h2\u003e\n\u003ch3\u003eCondition: New\u003c\/h3\u003e\n\u003ch3\u003eMPN\/Model: RBM-BT14FUL\u003c\/h3\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=HsSHrb_5c\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACA0QAA\" data-complete=\"true\"\u003eKey Specifications \u0026amp; Installation Guidelines\u003c!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],[],null,1]]--\u003e\n\u003c\/h3\u003e\n\u003ch3 data-sfc-root=\"c\" data-ved=\"2ahUKEwjq9P7Ntv6XAxVMrSsGHV-dH6MQi4wTegoIAggACAAIEBAB\" data-hveid=\"CAIIAAgACBAQAQ\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eProduct Type:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Heat Recovery T-Shape Branching Joint\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h3\u003e\n\u003ch3 data-sfc-root=\"c\" data-ved=\"2ahUKEwjq9P7Ntv6XAxVMrSsGHV-dH6MQi4wTegoIAggACAAIEBAH\" data-hveid=\"CAIIAAgACBAQBw\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eApplication:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Used for branching and connecting outdoor units in heat recovery systems (paired with companion kits like RBM-BT24FUL).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h3\u003e\n\u003ch3 data-sfc-root=\"c\" data-ved=\"2ahUKEwjq9P7Ntv6XAxVMrSsGHV-dH6MQi4wTegoIAggACAAIEBAN\" data-hveid=\"CAIIAAgACBAQDQ\" data-complete=\"true\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOrientation Rules:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBAQDw\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBAQEA\" data-complete=\"true\"\u003e\n\u003ch3\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSuction gas joints must be mounted horizontally (with a maximum gradient of ±15°).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h3\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBAQEQ\" data-complete=\"true\"\u003e\n\u003ch3\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDischarge gas, liquid, and balance pipe joints have no orientation restrictions, provided the main pipe does not flow directly into a header unit.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/h3\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003ch3 data-sfc-root=\"c\" data-ved=\"2ahUKEwjq9P7Ntv6XAxVMrSsGHV-dH6MQi4wTegoIAggACAAIEBAN\" data-hveid=\"CAIIAAgACBAQDQ\" data-complete=\"true\"\u003e\n\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h3\u003e\n\u003ch3 data-sfc-root=\"c\" data-ved=\"2ahUKEwjq9P7Ntv6XAxVMrSsGHV-dH6MQi4wTegoIAggACAAIEBAW\" data-hveid=\"CAIIAAgACBAQFg\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eBrazing Requirements:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Must be purged with nitrogen prior to brazing to prevent oxidation scale and system cycle clogging; use clean, new R410A pipes.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h3\u003e\n\u003ch3 data-sfc-root=\"c\" data-ved=\"2ahUKEwjq9P7Ntv6XAxVMrSsGHV-dH6MQi4wTegoIAggACAAIEBAc\" data-hveid=\"CAIIAAgACBAQHA\" data-complete=\"true\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eInsulation:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Joints must be individually insulated; use heat resistance rated at ≥248°F for discharge gas pipes and a thickness of ≥0.4\" for seams and T-joints.\u003c\/span\u003e\u003c\/h3\u003e","brand":"TOSHIBA CARRIER","offers":[{"title":"Default Title","offer_id":68255974326509,"sku":"CW11034","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0602\/6461\/2077\/files\/IMG_8001_d6a070a0-3c81-4061-a233-d6bb29ced9a0.jpg?v=1794349432","url":"https:\/\/paywut.com\/products\/toshiba-carrier-t-shaped-heat-recovery-branching-joint-kit-rbm-bt14ful","provider":"PayWut","version":"1.0","type":"link"}